1000/1400 Series
PRINT E-MAIL BOOKMARK  

Veriteq 1000/1400 Series precision temperature data loggers are compact, powerful and easy-to-use temperature recorders for monitoring critical temperature-sensitive environments, products and processes. Each logger features an integral precision-tolerance thermistor temperature sensor with outstanding long-term stability, measurement sensitivity and responsiveness. Designed for use in a wide range of environments, the dataloggers can operate reliably under even the most extreme temperature conditions. What's more, the ten-year battery ensures that your data logger won't quit in the middle of a critical monitoring session.

Veriteq software is required to setup the data logger and download data collected.


  ENQUIRY
MODELS

Product description Code
VL-1000 tamper-proof logger for the Pharmaceutical/Biotech industry VVL100021N
VL-1000 tamper-proof logger for the Pharmaceutical/Biotech industry with 1 internal probe and 1 N-type external probe. Software to be used: vLog VVL100021N1
VL-1000 tamper-proof logger for the Pharmaceutical/Biotech industry with 1 N-type external probe. Software to be used: vLog VVL100022N1
VL-1000 tamper-proof logger for the Pharmaceutical/Biotech industry with 1 L-type external probe. Software to be used: vLog VVL100022L1
VL-1000 tamper-proof logger for the Pharmaceutical/Biotech industry with 1 V-type external probe. Software to be used: vLog VVL100022V1
VL-1000 tamper-proof logger for the Pharmaceutical/Biotech industry with 2 N-type external probes. Software to be used: vLog VVL100022N2
VL-1000 tamper-proof logger for the Pharmaceutical/Biotech industry with 2 L-type external probes. Software to be used: vLog VVL100022L2
VL-1000 tamper-proof logger for the Pharmaceutical/Biotech industry with 2 V-type external probes. Software to be used: vLog VVL100022V2
VL-1400 tamper-proof logger for the Pharmaceutical/Biotech industry with 4 N-type external probes. Software to be used: vLog VVL140044N4
VL-1400 tamper-proof logger for the Pharmaceutical/Biotech industry with 4 L-type external probes. Software to be used: vLog VVL100044L4
VL-1400 tamper-proof logger for the Pharmaceutical/Biotech industry with 4 V-type external probes. Software to be used: vLog VVL100044V4
SP-1000 logger with 1 internal probe.
Software to be used: Spectrum
VSP100021N
SP-1000 logger with 1 internal probe and 1 N-type external probe. Software to be used: Spectrum VSP100021N1
SP-1000 logger with 1 N-type external probe.
Software to be used: Spectrum
VSP100022N1
SP-1000 logger with 1 N-type external immersion probe.
Software to be used: Spectrum
VSP100022NIM1
SP-1000 logger with 1 L-type external probe.
Software to be used: Spectrum
VSP100022L1
SP-1000 logger with 1 L-type external immersion probe.
Software to be used: Spectrum
VSP100022LIM1
SP-1000 logger with 1 V-type external probe.
Software to be used: Spectrum
VSP100022V1
SP-1000 logger with 2 N-type external probes.
Software to be used: Spectrum
VSP100022N2
SP-1000 logger with 2 N-type external immersion probes.
Software to be used: Spectrum
VSP100022NIM2
SP-1000 logger with 2 L-type external probes.
Software to be used: Spectrum
VSP100022L2
SP-1000 logger with 2 L-type external immersion probes.
Software to be used: Spectrum
VSP100022LIM2
SP-1000 logger with 2 V-type external probes.
Software to be used: Spectrum
VSP100022V2
VL-1400 logger with 4 N-type external probes.
Software to be used: vLog
VSP140044N4
VL-1400 logger with 4 L-type external probes.
Software to be used: vLog
VSP100044L4
VL-1400 logger with 4 V-type external probes.
Software to be used: vLog
VSP100044V4

 


MORE INFORMATION

FEATURES

Product details for 1000/1400 SERIES
bullet Multiple options to choose from based on requirement. Powerful graphing,
  analysis, logger setup and reporting software
Productseperator
bullet Completely self-contained temperature data logger with internal sensor,
  memory and 10-year battery
Productseperator
bullet High-stability temperature sensor offers exceptional long-term data logger
  accuracy and in-calibration performance
Productseperator
bullet Traceable instrument-grade temperature measurement accuracy
Productseperator
bullet Two year limited warranty
Productseperator
bullet Adjustable logging intervals with 10-year temperature recording capacity
Productseperator
bullet External input for remote temperature probe flexibility
Productseperator
bullet Flexible software options include viewLinc (real-time monitoring & directly
  alarming over an ethernet network), Palm PDA connectivity, ability to work
  within excel and more

SPECIFICATIONS

Product specifications for 1000/1400 SERIES
Calibrated measurement range Internal probe: -25°C to +70°C
Type N external probe: 0.02°C @ +25°C
Type L external probe: 0.02°C @ +25°C
Type V external probe: 0.02°C @ +25°C
Instrument temperature accuracy (1 year)

Internal probe:
± 0.15°C over +20°C to +30°C
± 0.25°C over -25°C to +70°C
Type N external probe: 
± 0.15°C over +20°C to +30°C
± 0.25°C over -25°C to +70°C
Type L external probe: ± 0.25°C over -50°C to +10°C
Type V external probe: ± 0.25°C over -90°C to -40°C

Resolution 0.02°C @ +25°C
Clock accuracy ±1 min/month at 0–50°C
Memory size 48,100 12-bit samples (1000 series); 85,300 12-bit samples (1400 series)
Memory protection Data retention > 20 years backup without power
Memory modes User-selectable. Wrap (FIFO) or stop when memory is full. User selectable start/stop time
Data setup and offload VL series data logger is compatible with vLog & viewLinc (for on-going monitoring & alarming). SP series data logger is compatible with the following software packages: Spectrum, viewLinc (for on-going monitoring & alarming), Veriteq sGo (for Palm OS), Spectrum Excel Add-in and Spectrum API (for custom applications)
Data communication RS-232 serial port, Ethernet, PoE
Power source Internal Lithium battery with life of 10 years at 1 minute sampling rate
Enclosure Injection-molded beige ABS plastic
Communication: USB
Dimensions 89 x 59 x 26mm
Weight 60gm

DOWNLOADS

Documentation and software downloads for 1000/1400 SERIES
Data Sheet 1000/1400 Series

ACCESSORIES

Recommended accessories for 1000/1400 SERIES
Product description Code
A2LA accredited NIST traceable calibration VCA1x00
vLog Version 4.21 software with USB cable VSWUSBD421
IQ/OQ validation protocol for vLog software 4.21 VDOCVP6
Spectrum software with USB cable VSWSPUSBD
viewLinc software – starter license VSWVWLST
viewLinc software – server license VSWVWLSR
NEMA 4X (IP66) rated enclosure VACENC01
USB cable VUSBDB9
Serial cable VDB96
Ethernet adapter, 1 port VEAD1
Ethernet adapter, 2 port VEAD2
Ethernet adapter, 4 port VEAD4
Ethernet adapter, 8 port VEAD8
Wireless ethernet adapter, 1 port VWEAD1
© 2008 Easy Solutions, All rights reserved.