4000 Series
PRINT E-MAIL BOOKMARK  

Veriteq 4000 Series Thermocouple data loggers are miniature stand-alone devices designed to interface with a wide range of third party transducers, transmitters and sensors emitting DC voltage or 4-20mA current loop output.

A screw-type terminal block makes sensor connections to the logger simple. Available in single channel or 4-channel versions, each device is based on proven Spectrum 12-bit logger platform that provides superb resolution and accuracy over the widest measurement ranges.

Multiple software options are available to choose from based on whether the device is for continuous monitoring or for spot checks. Wireless communication option also available.


  ENQUIRY
MODELS

Product description Code
SP-4000 single channel 4-20mA data logger   VSP40001CW
SP-4000 four channels 4-20mA data logger VSP40004CW
SP-4000 single channel 0-10VDC data logger VSP4000101
SP-4000 four channels 0-10VDC data logger VSP4000411
SP-4000 four channels data logger, two 0-10VDC & two 4-20mA VSP4000

 


MORE INFORMATION

FEATURES

Product details for 4000 SERIES
bullet Single & multi-channel models offer up to 4 input channels
Productseperator
bullet Self-powered, long-life 10-year battery
Productseperator
bullet Scale and measurement units are user configurable
Productseperator
bullet Current loop XPS excitation control switch for powering of external
  transducers
Productseperator
bullet High accuracy, adjustable time-based digital recording
Productseperator
bullet 70,600 sample memory
Productseperator
bullet Two year limited warranty

SPECIFICATIONS

Product specifications for 4000 SERIES
Measurement range Current loop: 0–22mA
Analog voltage: 0–1V, 0-10VDC
Inbuilt temperature sensor: -20°C-+70°C
Accuracy ±0.15%FS at +25°C for current loop and analog voltage
±0.25°C over +20°C-+30°C, ±0.35°C over -20°C-+70°C
Resolution Current loop: 5.5mA
Analog voltage: 0.025%FS
Inbuilt temperature sensor: 0.02°C at +25°C
Clock accuracy ±1 min/month at 0–50°C
Input impedance Current loop: 50-Ohms
Analog voltage: >1MOhm
Isolation One common per logger
Overload protection Current loop: 60mA max. (reverse polarity protected)
Analog voltage: ±30V max. (reverse polarity protected)
Memory size 70,600 12-bit samples
Memory type Non-volatile EEROM
Memory modes User-selectable. Wrap (FIFO) or stop when memory is full. User selectable start/stop time
Data setup and offload SP4000 series data logger is compatible with the following software packages: Spectrum, viewLinc (for on-going monitoring & alarming), Veriteq sGo (for Palm OS), Spectrum Excel Add-in and Spectrum API (for custom applications)
Data communication RS-232 serial port, Ethernet, PoE, WiFi network interface available
Power source Internal Lithium battery with life of 10 years at 1 minute sampling rate
Enclosure Injection-molded ABS plastic
Dimensions 71 x 53 x 20mm
Weight 65gm

DOWNLOADS

Documentation and software downloads for 4000 SERIES
Data Sheet 4000 Series

ACCESSORIES

Recommended accessories for 4000 SERIES
Product description Code
Spectrum software with USB cable VSWSPUSBD
USB cable VUSBDB9
Serial cable VDB96
© 2008 Easy Solutions, All rights reserved.