7000 Series UID
PRINT E-MAIL BOOKMARK  

SL7000 Series data logger accepts from 1 to 4 universal inputs, based on the model chosen. Moreover all the 7000 series datalogger have an internal temperature and digital input which can be used as trigger to start logging or as pulse counter.

An optional on-board LCD display shows selected channel information and the integrated LED displays provide immediate scanning and alarm status information. The device is powered by a built-in battery with a life of 6 years. Up to 128,000 readings can be stored in the logger.

Temp-IT Pro software allows for data to be viewed on the desktop computer as well as to program the devices. Its also possible to connect multiple 7000 series device through a network to the software.


  ENQUIRY
MODELS

Product description Code
7000 Series data logger with internal temperature sensor only E7001
7000 Series data logger with 2 universal inputs & internal temperature sensor E7002
7000 Series data logger with 2 universal inputs & internal temperature & Internal RH E7003
7000 Series data logger with 4 universal inputs & internal temperature sensor E7004
7000 Series data logger with 4 universal inputs & internal temperature & Internal RH E7005
7000 Series data logger with internal temperature sensor only + LCD Display E7100
7000 Series data logger with internal temperature and internal relative humidity sensors + LCD Display E7101
7000 Series data logger with 2 universal inputs & internal temperature sensor + LCD Display E7102
7000 Series data logger with 2 universal inputs & internal temperature & Internal RH + LCD Display E7103
7000 Series data logger with 4 universal inputs & internal temperature sensor + LCD Display E7104
7000 Series data logger with 4 universal inputs & internal temperature & Internal RH + LCD Display E7105

 


MORE INFORMATION

FEATURES

Product Details for 7000 Series
bullet Universal Inputs
Productseperator
bullet Storage limit of up to 128,000 readings
Productseperator
bullet 16-bit resolution
Productseperator
bullet LCD display option
Productseperator
bullet User-replaceable battery with typical 3 year life
Productseperator
bullet Digital input can be used as an event trigger or as a counter input
  enabling counts up to 65535 per period
Productseperator
bullet Sampling time of 1 second to 24 hours
Productseperator
bullet Possible to network up to 64 devices

SPECIFICATIONS

Product specifications for GL800 Universal Input Datalogger
Input Variations Internal Temperature and counter Internal Temperature + RH and counter

Internal Temperature, 2 Channel Universal and counter

Internal Temperature + RH, 2 Channel Universal and counter

Internal Temperature, 4 Channel Universal and counter

Internal Temperature, RH, 4 Channel Universal and counter

+Additional External Temp and RH option on all versions
Universal Input (maximum 4) Pt 100: 2 or 3 Wire °C or °F (BS EN 60751/JIS1604)

Ni100, Ni120: 2 or 3 Wire °C or °F

Cu100: 2 or 3 Wire °C or °F

Thermocouples Types J, K, T, R, S, B, N °C or °F

Thermistor (Various Types) °C or °F

(0 to 20) mA Scaled in engineering units

±100mVdc Scaled in engineering units

(0 to 1)Vdc Scaled in engineering units

(0 to 10) Vdc Scaled in engineering units

Slidewire Scaled in engineering units (100 ohm to 10Kohm)
Resolution All Universal Inputs - 16 Bit1
Internal & External Temperature - 12 Bit
Internal & External Relative Humidity - 8 Bit
Measrement range

Internal Temperature: -30°C to +70°C

Internal Relative Humidity: 0 to 100%RH
External Temperature: -30°C to +70°C
External Relative Humidity: 0 to 100%RH
RTD (Pt100) EN 60751: -200°C to +700°C
RTD (Pt100): JISC -100°C to +457°C
Thermocouple Type K: -200°C to +1370°C
Thermocouple Type J: -200°C to +1200°C
Thermocouple Type T: -200°C to +400°C
Thermocouple Type S: 100°C to +1760°C
Thermocouple Type R: 100°C to +1760°C
Thermocouple Type B: +700°C to 1820°C
Thermocouple Type N: -180°C to +1300°C
Ni120: -80°C to +230°C
Ni100: -60°C to +180°C
Cu10: -200°C to +260°C
Cu100: -100°C to +260°C
Thermistor (TH-001): -40°C to +140°C
Slidewire: 0 to 100%
Millivolt: (mV) -110mV to +110mV (Over Voltage protected to 24VDC)
10 Volt: 0VDC to 11VDC (Over Voltage protected to 24VDC)
1 Volt: 0VDC to 1.1VDC (Over Voltage protected to 24VDC)
4/20mA: 0.1 to 21mA
Pulse Counter: Up to 65,535 pulses per sample period
Operating Range -30°C to +80°C
Accuracy Internal Temp:± 0.5°C (-30°C to +70°C)
External* Temp:± 0.4°C @ +25°C, ±1.75°C (-30°C to +70°C)
Internal/External RH:± 2.0%RH over 10%-90%
± 4.0% RH over the range 0-10% and 90-100%RH
Pt100 2 or 3 Wire °C or °F: ± 0.1°C ± 0.1% rdg
Ni100/Ni120*/Cu100*:± 0.2°C ± 0.1% rdg
Slidewire:± 0.02% FSD
0/20mA:± 0.01% FSD
±100mVdc:± 0.01% FSD
0/1Vdc:± 0.01% FSD
0/10Vdc:± 0.01% FSD
Thermistor (Various Types, °C or °F):Type dependent contact sales office for details
Thermocuples J, K, T and N: (°C or °F):± 0.1% FSD ± 0.5°C
Thermocouples R, S and B (°C or °F):± 0.2% FSD ± 0.5°C
Memory Size 0 or 2 Universal Inputs - 62,000 Readings 4 Universal Inputs - 128,000 Readings

Battery

Lithium AA (3.6V DC) 2.7 Ah User replacable
Battery Life Typically 6 Years (2700mAh)
Manifest Text (User) 256 Characters
Manifest Text (Owner) 256 Characters
Alarm Setpoints Independent High and Low, Latching per channel
Alarm Trigger Time Each Setpoint has an associated time. This time dictates the period the alarm must be continuously present before the alarm is raised. The options are 0 to 255 sample periods
Event Trigger A programmable level per channel that will cause all channels to start recording when the input first crosses the threshold in the specified direction. An event can also be the exercising of an external digit signal or the activation of a magnetic swipe
Low Battery Warning Low Battery displayed when battery life has less than one month to go.
Dimensions 124 x 78 x 32mm
Weight 165gm

DOWNLOADS

Documentation and software downloads for 7000 Series
Data Sheet 7000 Series Data Sheet
Data Sheet 7000 Series Thermal Barrier Data Sheet

ACCESSORIES

Recommended accessories for 7000 Series
Product description Code
External temperature & relative humidity sensor EACC7000-01
Replacement / Additional USB lead EACC7000-02
Replacement Lithium Thionyl Chloride Battery EACC7000-03
E7000 External Power Supply EACC7000-04
Replacement / Additional 14 Way Connector EACC7000-05
Thermal Barrier for data logger (Temperature and exposure time to be defined by customer) E-TB
© 2008 Easy Solutions, All rights reserved.