| Input Variations |
Internal Temperature and counter
Internal Temperature + RH and counter
Internal Temperature, 2 Channel Universal and counter
Internal Temperature + RH, 2 Channel Universal and counter
Internal Temperature, 4 Channel Universal and counter
Internal Temperature, RH, 4 Channel Universal and counter
+Additional External Temp and RH option on all versions
|
| Universal Input (maximum 4) |
Pt 100: 2 or 3 Wire °C or °F (BS EN 60751/JIS1604)
Ni100, Ni120: 2 or 3 Wire °C or °F
Cu100: 2 or 3 Wire °C or °F
Thermocouples Types J, K, T, R, S, B, N °C or °F
Thermistor (Various Types) °C or °F
(0 to 20) mA Scaled in engineering units
±100mVdc Scaled in engineering units
(0 to 1)Vdc Scaled in engineering units
(0 to 10) Vdc Scaled in engineering units
Slidewire Scaled in engineering units (100 ohm to 10Kohm) |
| Resolution |
All Universal Inputs - 16 Bit1 |
| Internal & External Temperature - 12 Bit |
| Internal & External Relative Humidity - 8 Bit |
| Measrement range |
Internal Temperature: -30°C to +70°C |
| Internal Relative Humidity: 0 to 100%RH |
| External Temperature: -30°C to +70°C |
| External Relative Humidity: 0 to 100%RH |
| RTD (Pt100) EN 60751: -200°C to +700°C |
| RTD (Pt100): JISC -100°C to +457°C |
| Thermocouple Type K: -200°C to +1370°C |
| Thermocouple Type J: -200°C to +1200°C |
| Thermocouple Type T: -200°C to +400°C |
| Thermocouple Type S: 100°C to +1760°C |
| Thermocouple Type R: 100°C to +1760°C |
| Thermocouple Type B: +700°C to 1820°C |
| Thermocouple Type N: -180°C to +1300°C |
| Ni120: -80°C to +230°C |
| Ni100: -60°C to +180°C |
| Cu10: -200°C to +260°C |
| Cu100: -100°C to +260°C |
| Thermistor (TH-001): -40°C to +140°C |
| Slidewire: 0 to 100% |
| Millivolt: (mV) -110mV to +110mV (Over Voltage protected to 24VDC) |
| 10 Volt: 0VDC to 11VDC (Over Voltage protected to 24VDC) |
| 1 Volt: 0VDC to 1.1VDC (Over Voltage protected to 24VDC) |
| 4/20mA: 0.1 to 21mA |
| Pulse Counter: Up to 65,535 pulses per sample period |
| Operating Range |
-30°C to +80°C |
| Accuracy |
Internal Temp:± 0.5°C (-30°C to +70°C) |
| External* Temp:± 0.4°C @ +25°C, ±1.75°C (-30°C to +70°C) |
Internal/External RH:± 2.0%RH over 10%-90%
± 4.0% RH over the range 0-10% and 90-100%RH
|
| Pt100 2 or 3 Wire °C or °F:
± 0.1°C ± 0.1% rdg
|
| Ni100/Ni120*/Cu100*:± 0.2°C ± 0.1% rdg |
| Slidewire:± 0.02% FSD |
| 0/20mA:± 0.01% FSD |
| ±100mVdc:± 0.01% FSD |
| 0/1Vdc:± 0.01% FSD |
| 0/10Vdc:± 0.01% FSD |
| Thermistor (Various Types, °C or °F):Type dependent contact sales office for details |
| Thermocuples J, K, T and N:
(°C or °F):± 0.1% FSD ± 0.5°C
|
| Thermocouples R, S and B (°C or °F):± 0.2% FSD ± 0.5°C
|
| Memory Size |
0 or 2 Universal Inputs - 62,000 Readings
4 Universal Inputs - 128,000 Readings
|
Battery |
Lithium AA (3.6V DC) 2.7 Ah User replacable |
| Battery Life |
Typically 6 Years (2700mAh) |
| Manifest Text (User) |
256 Characters |
| Manifest Text (Owner) |
256 Characters |
| Alarm Setpoints |
Independent High and Low, Latching per channel |
| Alarm Trigger Time |
Each Setpoint has an associated time. This time dictates the
period the alarm must be continuously present before the alarm
is raised. The options are 0 to 255 sample periods
|
| Event Trigger |
A programmable level per channel that will cause all channels to
start recording when the input first crosses the threshold in the
specified direction. An event can also be the exercising of an
external digit signal or the activation of a magnetic swipe
|
| Low Battery Warning |
Low Battery displayed when battery life has less than one month
to go.
|
| Dimensions |
124 x 78 x 32mm
|
| Weight |
165gm
|