| Hotbox SE |
|
All-purpose Hotbox SE is ideal for service technicians to use at locations where fast, uncomplicated logging of process data is required. The programmable Hotbox SE measures parameters such as pressure, temperature, humidity, carbon dioxide, differential pressure and various other 4 to 20mA or DC Voltage signals.
It is possible to connect 2 temperature sensors, 2 probes with 4 to 20mA and 2 sensors with DC voltage signals. The large display shows the values measured by the sensor, in units of measurement selected by the customer. Any 4 channels can be selected for data recording. The device has a storage capacity of 64,000 data points. Data from the logger can be downloaded to a PC for further analysis using elproLOG software.
|
|
|
MODELS
|
| Product description |
Code |
| Hotbox SE universal logger for signals, calibration certificate included |
E2501 |
| Hotbox SE set (contains elproLOG PC ANALYZE Software, PC data cable ECOLOG and plastic suitcase) |
E2810SE |
|
MORE INFORMATION |
FEATURES
| Product details for Hotbox SE |
 |
Universal sensor connections for NTC temperature probes, 4 to 20mA and DC signals |
 |
 |
Any sensor can be programmed to trigger an external alarm |
 |
 |
Simple configuration |
 |
 |
Auto scroll LCD display |
 |
 |
64,000 sample memory |
 |
 |
Connection for protocol printer |
 |
 |
Unit and sensors powered by battery or external power supply |
 |
 |
On power save mode, unit switches off display and turns on only during |
| |
measurement |
 |
 |
Collected data can be downloaded to elproLOG software for further |
| |
analysis. Can also use the software to program the sensors |
SPECIFICATIONS
| Product specifications for Hotbox SE |
| Measurement range |
Temperature measurement with NTC thermistor: |
-50 to +140°C |
| Voltage measurement: |
0..100mV; 0..200mV; 0..500mV; 0..1V; 0..2V; ±100mV;±200mV; ±500mV;
±1V; ±2V; 0..5V; 0..10V; 0..20V;
±5V; ±10V; ±20V |
| Current measurement: |
0..20mA; 4..20mA |
| Resolution |
Temperature measurement with NTC thermistor:
|
0.1°C |
| Voltage measurement: |
0.1 mV (for ranges 0..100mV, 0..200mV, 0..500mV & ±100mV); 1mV (for ranges 0..1V, 0..2V and 0..5V); 0.1/1mV (for ranges ±200mV and ±500mV); 1/10mV (for ranges ±1V, ±2V and ±5V); 10mV (for ranges 0..10V, 0..20V and ±10V); 10/100mV (for the range ±20V) |
| Current measurement: |
0.1 mA |
| Accuracy |
Temperature measurement with NTC thermistor:
|
±0.4°C (-50 .. -25°C); ±0.3°C (-25 .. 0°C); ±0.2°C (0 .. 70°C); ±0.4°C (70 .. 100°C); ±0.7°C (100 .. 140°C) |
| Voltage measurement: |
0.5% ±5 digits ( for the range 0..100mV,
±100mV); 0.5% ±3 digits (for the range 0..200mV, 0..500mV, ±200mV and
±500mV); 0.2% ±2 digits (for the range 0..1V, 0..2V, ±1V and ±2V); 0.3% ±3 digits (for the range 0..5V, 0..20V,
±5V and ±20V); 0.2% ±3 digits (for the range 0..10V and ±10V) |
| Current measurement: |
0.2% ±1 digit |
| Operating temperature |
-35 to +55°C, display readable down to -20°C |
| Memory capacity |
64,000 data points |
| Display |
LCD display. Shows date, time, alarm status, upper/lower threshold value violated, sensor number, measured value with unit and progress bar |
| Protection |
IP30 |
| Dimensions |
249 x 92 x 30mm |
| Data setup and offload |
elproLOG PC software (Windows 98/2000/ME/XP/NT 4.0 or higher/Vista) |
|
DOWNLOADS
| Documentation and software downloads for Hotbox SE |
|
ACCESSORIES
| Recommended accessories for Hotbox SE |
| Product description |
Code |
| Hygroclip S for Temperature & RH (0..100%RH, -20°C..+60°C); calibration certificate included |
E3088A |
Hygroclip S1 for Temperature & RH (+/-1%RH)
(0..100%RH, -20°C..+60°C); calibration certificate included |
E3088B |
Hygroclip SC05 sensor for Temperature & RH (0..100%RH,
-40°C..+100°C, D=5mm); calibration certificate included |
E3089A |
| 1m Hygroclip cable with 7p connector |
E3216L01 |
| 2m Hygroclip cable with 7p connector |
E3216L02 |
| 5m Hygroclip cable with 7p connector |
E3216L05 |
| Air speed sensor, 0.3..20m/s, MINI D22 x 28mm, 0..2VDC |
E3264 |
| Ampere clamp Mini2 for 1..150Amp. AC |
E3268 |
| Ampere clamp YCV5 for 2..500Amp. AC |
E3269 |
| Pressure sensor, 1..9bar |
E3280A |
| Pressure sensor, 1..24bar |
E3280B |
| Power supply with stabilisied output voltage input 90-240VAC, plug Euro, output 12VDC, 0.5A |
E2832D |
| Power supply; 100..240VAC/24VDC, 0.35A |
E2832 |
| Mounting plate, Size: 289 x 240 x 25mm |
E2804SE1 |
| Mounting of 1-2 sensors to connector |
E2540B |
IP66 rated waterproof housing, plastic shockproof,
(22 x 18 x 11cm), cover transparent with quick lock, cable clamps
2 x PG7 and 1 x PG9 |
E2350A |
| DB15 socket for ECOLOG, with terminals for customer installation |
E3034 |
| DB15 socket, AMP metal, for ECOLOG, with connector for soldering, no pre-wiring |
E3032 |
| Replacement Lithium battery, 3.6V-1.9Ah, shelf life 5 years min. |
E2820 |
| USB to RS232 converter connecting data logger to PC |
E2317USB |
| PC data cable |
E2318 |
| Connector for 2 NTC sensors |
E2540P4 |
| Connector for 2 pressure transmitters |
E2540P5 |
|
|
|