EZ700 Series Analog Input Logger
PRINT E-MAIL BOOKMARK  

EZ700 is a versatile data logger for easy recording of common process signal variables. With seven input channels, the logger is ideal for monitoring (through commercially available transducers) a wide variety of measurement parameters including temperature, humidity, pressure, wind speed, current, voltage, power, and much more.

Powered by an internal lithium battery that lasts for up to 10 years and multiple internal memory options, these loggers are network capable, modem accessible and wireless ready. An interface cable allows the loggers to be connected to the logger so that it can be configured using Trendzlog software in a matter of minutes. The software also provides a real time snapshot of the logged data.


  ENQUIRY
MODELS

Product description  Channel Description Code
EZ700 data logger with 32kB memory (Standard version) 0 to 2.5V DC (1 channel) 0 to 5V DC (2 channels) 0 to 10V DC (1 channel) 0 to 200mV DC (1 channel) 0 to 25mA DC (2 channels) EZ700-S-32
EZ700 data logger with 128kB memory (Standard version) 0 to 2.5V DC (1 channel) 0 to 5V DC (2 channels) 0 to 10V DC (1 channel) 0 to 200mV DC (1 channel) 0 to 25mA DC (2 channels) EZ700-S-128
EZ700 data logger with 1.5MB memory (Standard version) 0 to 2.5V DC (1 channel) 0 to 5V DC (2 channels) 0 to 10V DC (1 channel) 0 to 200mV DC (1 channel) 0 to 25mA DC (2 channels) EZ700-S-1.5
EZ700 data logger with 32kB memory
(0-2.5V DC)
0 to 2.5V DC (7 channels) EZ700-2.5-32
EZ700 data logger with 128kB memory
(0-2.5V DC)
0 to 2.5V DC (7 channels) EZ700-2.5-128
EZ700 data logger with 32kB memory 
(0-5V DC)
0 to 5V DC (7 channels) EZ700-5-32
EZ700 data logger with 128kB memory
(0-5V DC)
0 to 5V DC (7 channels) EZ700-5-128
EZ700 data logger with 1.5MB memory 
(0-5V DC)
0 to 5V DC (7 channels) EZ700-5-1.5
EZ700 data logger with 32kB memory 
(0-10V DC)
0 to 10V DC (7 channels) EZ700-10-32
EZ700 data logger with 128kB memory
(0-10V DC)
0 to 10V DC (7 channels) EZ700-10-128
EZ700 data logger with 1.5MB memory 
(0-10V DC)
0 to 10V DC (7 channels) EZ700-10-1.5
EZ700 data logger with 32kB memory 
(0-25mA DC)
0 to 25mA DC (7 channels) EZ700-25-32
EZ700 data logger with 128kB memory
(0-25mA DC)
0 to 25mA DC (7 channels) EZ700-25-128
EZ700 data logger with 1.5MB memory
  (0-25mA DC)
0 to 25mA DC (7 channels) EZ700-25-1.5

MORE INFORMATION

FEATURES

Product Details for EZ700 Series Analog Input Logger
bullet Eight Channels
Productseperator
bullet Connect virtually any device that has an analog output allowing the
  ability to lrecord a variety of parameters (i.e. flow, level, pressure, etc.)
Productseperator
bullet Several different models to choose from
Productseperator
bullet Up to 25 samples per second
Productseperator
bullet 12-bit resolution
Productseperator
bullet 10-year battery life
Productseperator
bullet Up to 1.5 MB memory
Productseperator
bullet Alarm Dial Out
Productseperator
bullet User configurable
Productseperator
bullet Network capable. Also possible to access remotely by modem

SPECIFICATIONS

Product Specifications for Smart Reader plus-7

Channels

Eight: One internal thermistor and 7 analog inputs
Memory Size Available in 32 KB (21,500 readings), 128 K (87,000 readings)  or 1.5 MB (1,048,000 readings) versions <
Size 107 x 74 x 22 mm. (4.2” x 2.9” x 0.9”)
Weight 110 grams
Case Material Noryl® Plastic
External Connector Removable screw-type terminal strip with Common (-) connection
Operating Limits -40°C to 70°C and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy ±2 seconds per day
Battery 3.6 volt Lithium, 1 Amp-Hour
Battery Life 10 year warranty (under normal use), factory replaceable
Power Consumption 5 to 10 micro amps (continuous)
Sampling Methods 1. Continuous (First-in, First-out – not available with sample rates faster than 8 seconds)
2. Stop when full (Fill-then-stop)
Sampling Rates User selectable rates from 25 per second to 1 reading every 8 hrs. (Battery Pack or Power Supply required for sample rates faster than 8 seconds)
Resolution 12 bit (1 part in 4,096)
Mounting Magnetic backing or locking eyelet
Software Trendzlog 1
PC Requirements MS Windows XP or Vista 32-bit with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port
Analog Input Specifications
Maximum Protection Voltage channels: ±40V (reverse polarity protected) Current channels: ±70mA (reverse polarity protected)
Accuracy ±0.5% of full scale
Transducer Restrictions The use of a single power supply is recommended to avoid ground loops or use loop isolators
Internal Temperature Sensor
Type Negative Temperature Coefficient Thermistor.  10,000 ohms @ 25°C
Accuracy ± 0.2°C, over the range of 0 to 70°C
Range -40 to 70°C
Resolution 0.03°C at 25°C. Better than 0.07°C between -25°C and 70°C. Better than 0.13°C between -40°C and -25°C
Analog Input Specifications
Input Impedance for Analog Input Channels
Input Type Input Impedance
0 to 2.5 volts DC Greater than 1M ohm
0 to 5.0 volts DC Greater than 1M ohm
0 to 10.0 volts DC Greater than 1M ohm
0 to 200 millivolts DC Greater than 1M ohm
0 to 25 milliamps DC 20 Ohm

DOWNLOADS

Documentation downloads for EZ700 Series Analog Input Logger
Data Sheet EZ700 Series Analog Input Logger

ACCESSORIES

Recommended accessories for EZ700 Series Analog Input Logger
Product description Code
Battery pack (require for log at rate faster than once every 8 seconds) EZBP-101
Display module,smart reader plus EZSRPDM
Power supply for display module EZ33-0016
Voltage transducer ( Converts a three phase, 600 VAC, 60 Hz power system to three proportional 0 to 5 volt DC outputs). EZVT-3P
USB interface cable EZIC-102
Serial Interface EZIC-101
Trendzlog software EZTR2
© 2008 Easy Solutions, All rights reserved.