EZ90 Pulse data Logger
PRINT E-MAIL BOOKMARK  

The EZ90 data logger is a three channel data logger. An internal temperature sensor records ambient temperature and two channels designed for counting and recording digital pulse or switch contact closures.

These loggers can be used to trace number of times a switch opens and closes by maintaining a voltage potential across the input terminals on a continual basis. Each device is powered by an internal lithium battery that lasts for up to 10 years.

These loggers can be used as a stand-alone device or as a part of a network of loggers giving you access to real time data. The software allows the user to also display the data in custom engineering unit.


  ENQUIRY
MODELS

Product description Code
EZ90 Pulse data logger with 32kB memory EZ90-32

 


MORE INFORMATION

FEATURES

Product Details for EZ90 Pulse Logger
bullet Three Channels
Productseperator
bullet Use for real time monitoring or stand alone monitoring.
Productseperator
bullet Very Light Weight. Weighs only 110gm.
Productseperator
bullet 8 Bit Resolution.
Productseperator
bullet 10 year long battery life for versatile monitoring periods.
Productseperator
bullet Capable of storing more than 32,000 readings
Productseperator
bullet User selectable rates from once every 8 seconds to once every 5 days

SPECIFICATIONS

Product specifications for EZ90 Pulse Logger
Channels Three channels
 • One Internal temperature sensor
 • Two external inputs for pulse signal or dry switch contact closures
    for remote sensing of resistance or switch status.
Memory Size 32 KB (More than 32,000 readings)
Size 107 x 74 x 22mm.
Weight 110 grams
External Connector Removable screw-type terminal strip with Common (-) connection
Operating Limits -40°C to 70°C and 0 to 95% Relative Humidity (non-condensing)
Clock Accuracy ±2 seconds per day
Battery 3.6 volt Lithium, 1 Amp-Hour
Battery Life 10 year warranty (under normal use), factory replaceable
Power Consumption 5 to 10 microamps (continuous)
Sampling Methods 1. Continuous (First-in, First-out)
2. Stop when full (Fill-then-stop)
Sampling Rates User selectable rates from once every 8 second to once every 5 days
Resolution 8 bit (1 part in 256)
Mounting Magnetic backing or locking eyelet
PC Requirements Compatible with MS Windows XP or Vista 32-bit with at least 2 MB RAM, 2 MB of hard drive disk space and one free serial port
Internal Temperature Sensor
Type Negative Temperature Coefficient Thermistor. 10,000 ohms @ 25°C
Accuracy ± 0.2°C, over the range of 0 to 70°C
Range -40 to 70°C
Resolution 0.4°C at 25°C; Better than 1°C between -25°C and 70°C; Better than 2°C between -40°C and -25°C
Pulse input channels
Switch Contact type Uncommitted switch or relay contacts
Logic Input type Active logic signals
Range 32 pulse/seconds
64 pulse/seconds
128 pulse/seconds
Minimum pulse width 4 milliseconds
Input Voltage Low = 0 to 0.5 volts DC
High = 4.5 to 24 volts DC
Input Impedance 750 K ohms

DOWNLOADS

Documentation downloads for EZ90 Pulse Logger
Data Sheet EZ90 Pulse Logger

ACCESSORIES

Recommended accessories for EZ90 Pulse Logger
Product description Code
Stereo Y-adapter 01-0098
Male-Female 20ft Extension Cable 31-0024
USB interface Cable to Data Logger EZIC-102
Trendreader software EZTRS
Real time Software EZRTS
Serial interface (DB9 Female) cable to Data Logger EZIC-101
Terminal Block – 11 pin EZTB -11
© 2008 Easy Solutions, All rights reserved.